Calibration 2  ?Calibration 2 : cWLgreen =0.602 How nice! | Calibration 2 - Now let's pay attention to the effective wavelength
- -cWL/0.500/0.602/0.500/0.500_AutoCAL
- see that cWLgreen =was set at 0.602 by AutoCAL
- WLgreen=577.76 nm
- this seems to suit the calibration quite well
- increase or decrease cWLgreen , and inspect the result
- like cWLgreen =0.50 (see below)
- like cWLgreen =0.70 (see below)
|
cWLgreen =0.50 at mid-waveband - WLgreen=569.50 nm is too short
- as illustrated by the Z2 vs Z3 insert:
- Kgreen is too low
Notice that the Z1,2,3 vs Z4 are not affected | cWLgreen =0.70 - WLgreen=585.70 nm is too long
- as illustrated by the Z2 vs Z3 insert:
- Kgreen is too high
Notice that the Z1,2,3 vs Z4 are not affected |
This aspect is now well understood: see 4SM 2K Jerlov | This aspect is now well understood: see 4SM 2K Jerlov |